You are here: Home >> Products >> Frequency Inverter >> EM11 Series Vector Frequency Inverter
Products
EM11-G/P series vector frequency inverter
Model:EM11-G/P Series
Product Features:
EM11 series frequency inverter is based on the accurately understanding of EMHEATER for customers requirements, inheriting the consistent pursuitof EMHEATER for high-quality, high reliability. EM11 series frequency inverter will bring you a new using experience with its excellent performance and powerful features.
Product characteristics Product Specifications Application industry

Standard functions

l Maximum frequency: Vector control: 0~300 Hz; V/F control: 0~3000 Hz

l Carrier frequency: 0.5–16 kHz (automatically adjusted based on the load features.)

l Input frequency resolution: Digital setting: 0.01 Hz; Analog setting: maximum frequency x 0.025%.

l Control mode: Sensor-less vector control (SFVC); Closed-loop vector control (CLVC); Voltage/Frequency (V/F) control

l Startup torque: G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC); P: 0.5Hz/100%;

l Speed range: 1:100 (SFVC); 1:1000(CLVC)

l Speed stability accuracy: ± 0.5% (SFVC); ± 0.02% (CLVC)

l Torque control accuracy: ± 10% (SFVC); ± 5% (CLVC)

l Overload capacity:

G type: 60s for 150% of the rated current, 3s for 180% of the rated current;

P type: 60s for 120% of the rated current, 3s for 150% of the rated current

l Torque boost: Auto boost; Manual boost 0.1%~30.0%.

l V/F separation: Two types: complete separation; half separation.

l DC braking: DC braking frequency: 0.00 Hz ~ maximum frequency; Braking time: 0.0s~36.0s; Braking trigger current value: 0.0%~100.0%.

l Built-in simple PLC, multiple speeds: It realizes up to 16 speeds via the simple PLC function or combination of DI terminal states.

l Built-in PID: It realizes closed loop control system easily.

l Auto voltage regulation (AVR): It can keep constant output voltage automatically when the mains voltage fluctuation.

l Overvoltage/ Over current stall control: The current and voltage are limited automatically during the running process so as to avoid frequently tripping due to overvoltage / over current.

l Rapid current limit function: It can auto limit running current of frequency inverter to avoid frequently tripping. 

l Torque limit and control: (Excavator characteristics) It can limit the torque automatically and prevent frequently over current tripping during the running process. Torque control can be implemented in the VC mode.
 

Display and keypad operation

l LED display: It displays the parameters.

l LCD display: It is optional, supports panel display in Chinese or English language.

l Parameters copy: Optional LCD keypad can copy parameters.

l Key locking and function selection: It can lock the keys partially or completely and define the function range of some keys so as to prevent misoperation.

l Protection mode: Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, less voltage protection, overheat  protection and overload protection,etc.


Environment

l Installation location: Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt.

l Altitude: Lower than 1000 m.

l Ambient temperature: -10°C~ +40°C (de-rated if the ambient temperature is between 40°C and 50°C)

l Humidity: Less than 95%RH, without condensing.

l Vibration: Less than 5.9 m/s2 (0.6 g)

l Storage temperature: -20°C ~ +60°C

 
Model

Adaptable Motor

Input Current (A)

Output Current(A)

Power Capacity (KVA)

Thermal Power Consumption (KW)

KW
HP

Single-phase 220V50/60Hz

EM11-G1-d75
0.75
1.0
8.2
4
1.5
0.030
EM11- G1-1d5
1.5
2.0
14
7
3.0
0.055
EM11- G1-2d2
2.2
3.0
23
9.6
4.0
0.072

Three-phase 220V50/60Hz

EM11-G2-d75
0.75
1
5
3.8
3
0.030
EM11- G2-1d5
1.5
2
5.8
5.1
4
0.055
EM11- G2-2d2
2.2
3
10.5
9
5.9
0.072
EM11- G2-004
3.7
5
14.6
13
8.9
0.132
EM11- G2-5d5
5.5
7.5
26
25
17
0.214
EM11- G2-7d5
7.5
10
35
32
21
0.288
EM11- G2-011
11
15
46.5
45
30
0.489
EM11- G2-015
15
20
62
60
40
0.608
EM11- G2-018
18.5
25
76
75
57
0.716
EM11- G2-022
22
30
92
91
69
0.887
EM11- G2-030
30
40
113
112
85
1.11
EM11- G2-037
37
50
157
150
114
1.32
EM11- G2-045
45
60
180
176
134
1.66
EM11- G2-055
55
75
214
210
160
1.98
EM11- G2-075
75
100
307
304
231
2.02

Three-phase 380V50/60Hz

EM11- G3-d75
 
0.75
1
3.4
2.1
1.5
0.027
EM11- G3-1d5
EM11- P3-1d5
1.5
2
5
3.8
3
0.050
EM11- G3-2d2
EM11- P3-2d2
2.2
3
5.8
5.1
4
0.066
EM11- G3-004
EM11- P3-004
3.7
5
10.5
9
5.9
0.120
EM11- G3-5d5
EM11- P3-5d5
5.5
7.5
14.6
13
8.9
0.195
EM11- G3-7d5
EM11- P3-7d5
7.5
10
20.5
17
11
0.262
EM11- G3-011
EM11- P3-011
11
15
26
25
17
0.445
EM11- G3-015
EM11- P3-015
15
20
35
32
21
0.553
EM11- G3-018
EM11- P3-018
18.5
25
38.5
37
24
0.651
EM11- G3-022
EM11- P3-022
22
30
46.5
45
30
0.807
EM11- G3-030
EM11- P3-030
30
40
62
60
40
1.01
EM11- G3-037
EM11- P3-037
37
50
76
75
57
1.20
EM11- G3-045
EM11- P3-045
45
60
92
91
69
1.51
EM11- G3-055
EM11- P3-055
55
75
113
112
85
1.80
EM11- G3-075
EM11- P3-075
75
100
157
150
114
1.84
EM11- G3-090
EM11- P3-090
90
125
180
176
134
2.08
EM11- G3-110
EM11- P3-110
110
150
214
210
160
2.55
EM11- G3-132
EM11- P3-132
132
200
256
253
192
3.06
EM11- G3-160
EM11- P3-160
160
250
307
304
231
3.61
EM11- G3-200
EM11- P3-200
200
300
385
377
250
4.42
EM11- G3-220
EM11- P3-220
220
300
430
426
280
4.87
EM11- G3-250
EM11- P3-250
250
400
468
465
355
5.51
EM11- G3-280
EM11- P3-280
280
370
525
520
396
6.21
EM11- G3-315
EM11- P3-315
315
500
590
585
445
7.03
EM11- G3-355
EM11- P3-355
355
420
665
650
500
7.81
EM11- G3-400
EM11- P3-400
400
530
785
725
565
8.51
--
EM11- P3-450
450
600
883
820
630
9.23
Areas of application:
Electronics, textile, light industry, building materials, food, machinery, printing and dyeing, petrochemical, paper, logistics transportation, Wire drawing machine, winding machine, blow molding, chemical fiber, tobacco, grinder, mixer, extruding machine, injection molding machine, chemical industry, etc.